The UNITEx™-D Gland incorporates the MAC (Multi-Armour Captive Cone), providing an armour clamp and earth bond with Steel Wire, Braid and Tape armoured cables.
•For indoors, outdoors, Group II, III, Zone 1, 2, 20, 21 and 22 hazardous areas.
•Two-part handling, no loose part. A freely rotating captive cone and inspectable cone.
ring provide an armour clamp and earth bond on steel wire, aluminium, braid, and tape armour.
Equipment Protection Levels:
IECEx/INMETRO: Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da, Ex nR IIC Gc
ATEX/UKEX: II 2/3 G 1D, Ex db IIC Gb, Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
Deluge Protection: DTS-01
Marine: ABS IEC/EN 60079 Part 0, 1, 7, 15, 31 DNV IEC/EN 60079 Part 0, 1, 7, 15, 31
Protection: IP66 / IP68 (100m - Parallel) IEC 60529
Temperature Range: Standard -60°C to 95°C / Extreme -60°C to 160°C
Material (Gland): Brass / Marine Grade Electroless Nickel Plated™
Material (Seal): Standard Thermoset Elastomer or Extreme Temperature Seals